HomeAbout usFacilities
The C9920-02 absolute quantum yield spectrometer employs photoluminescence method to measure absolute quantum yields quick and accurately. The setup comprises an excitation light source, monochromator, an integrating sphere and a CCD spectrometer for detecting the whole spectral range...
The 1260 Infinity II LC System is a robust high performance liquid chromatography instrument that offers the widest choice of modules for analytical HPLC and entry-level UHPLC. It delivers the performance, reliability, and robustness you need for highest confidence in your daily results.
...The Agilent 5977C GC/MSD is a routine and reliable workhorse for chemical and analytical measurements, as well as the analysis of forensic and pharmaceutical compounds and allows labs to improve sample throughput. The 5977C single quadrupole GC/MS is built on the legacy of a series of trusted...
It can separate different substances of a complex mixture. In our laboratory, we commonly use it to assess the chemical reactivity of our materials. Our model, Agilent 6890N, offers a dual channel design with two different inlets. The column installed in the chromatograph is an Agilent...
Mettler Toledo TGA/SDTA 851e model that operates in the range 25 - 1100ºC provided with an ultramicrobalance with sensitivity of 0.1 ?g. Thermogravimetry (TGA) is a technique that measures the change in weight of a sample as it is heated or held at constant
With ALD, ultra-thin films are created through a precise, sequential exposure of a substrate to gas phase precursors, resulting in controlled layer-by-layer deposition with atomic proportions and pin-hole free morphology conformal to the substrate\'s shape. ALD finds...
A dedicated computational cluster configured for the execution of simulations. Hosted at the LluisVives-2 computational system of the University of Valencia. It has a partition for MPI calculations, 80 Intel Xeon CLX G-5218 four core nodes of 16C at 2.3GHz and 768 GB of DDR4 RAM.
A dedicated computational cluster configured for the execution of simulations. Hosted at the LluisVives-2 computational system of the University of Valencia. It has 8 NVIDIA A100 GPUs with 80 GB memory and passive PCle connection, 2 AMD 7313 processors with 16 cores each and frequency of 3GHz,...
Distinct extraction positions enable individual process control and simultaneous operation of 6 different extraction methods with high speed and reproducibility. Solvents: water, organic solvent with bp < 150°C.
The Rotavapor® R-300 meets the most stringent expectations for rotary evaporation convenience and versatility. Its modular design allows the R-300 to expand into a fully integrated system where a central interface regulates each component. Rotavapor® R-300 “intelligent...